What is sensor assignment

...

  • Timer sensor
  • HTTP sensor
  • Exception sensor
  • JDBC Connection sensor
  • JDBC Statement sensor
  • JDBC Prepared Statement sensor
  • JDBC Prepared Parameter sensor
  • Logging sensor for log4j
  • Image ModifiedInvocation sequence Sequence sensor (although this senor type exists it can not assigned directly, please check the Advanced sensor options below for more information) 

...

Annotation based instrumentation can be combined with all other instrumentation options. If the annotation option is used the Options column of the sensor assignment table will display this icon: Image Added.

Info
titleAnnotation class not needed on the class-path

The annotation class that is used in the instrumentation does not need to be on the class-path in order for instrumentation to work. 

Sensor specific options

Starts invocation

Applies to Timer sensor

As already mentioned the Image AddedInvocation Sequence sensor can not be applied directly to sensor assignment. Instead of this you can mark any Image AddedTimer sensor assignment to start the invocation as well as capturing the timing information. This is done by activating the Starts invocation option in the assignment sensor specific options. It's possible to optionally also set the minimum duration property. This property defines the minimum time an invocation has to consume in order to be saved and transmitted to the server. This helps in reducing the data load from the Agent to the CMR and is a good filter for not so important invocations.

Image Added

If the starts invocation is active the Options column of the sensor assignment table will display this icon: Image Added.

Charting

Applies to Timer and HTTP sensor

With the charting option it is possible to define what data should be considered as the long-term data available for charting in inspectIT User interface. This data is additionally saved to the database, thus even when the CMR is shutdown or buffer is cleared the data will be available via charts. With this approach it is possible to define exactly what methods performance data should be considered as long-term.

The configuration of the charting option is defined in the sensor assignment for Timer and HTTP sensor:

Image Added

If the charting option is active the Options column of the sensor assignment table will display this icon: Image Added.

Context capturing

Applies to Timer sensor

Please visit the Context capturing in sensor assignment for more information on context capturing option.