Excluded classes are marked as instrumented after update of exclude profile and agent restart

Description

Excluded profiles updates are not included in the moment in the dynamic instrumentation. Thus, agent restart is needed.

However, if a user update the exclude profile after an agent has connected and you exclude class that was instrumented, this one will not be marked as inactive in the instrumentation browser even when you restart the agent.

The fix is very simple, as we need better check in the MethodIdentToSensorType class with the information that we already have. There are no changes in the process or anything.

Environment

None

Assignee

Ivan Senic

Reporter

Ivan Senic

Labels

None

Integrator

Patrice Bouillet

Components

Sprint

None

Fix versions

Affects versions

Priority

Medium